| Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors. |
| Format string vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary code via format string specifiers in a message string. |
| Advantech/BroadWin WebAccess before 7.0 allows remote attackers to (1) enable date and time syncing or (2) disable date and time syncing via a crafted URL. |
| Cross-site request forgery (CSRF) vulnerability in Advantech/BroadWin WebAccess 7.0 allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-0235. |
| Buffer overflow in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary code via a long string value in unspecified parameters. |
| Stack-based buffer overflow in opcImg.asp in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary code via unspecified vectors. |
| uaddUpAdmin.asp in Advantech/BroadWin WebAccess before 7.0 does not properly perform authentication, which allows remote attackers to modify an administrative password via a password-change request. |
| Stack-based buffer overflow in NTWebServer.exe in the test web service in InduSoft NTWebServer, as distributed in Advantech Studio 6.1 and InduSoft Web Studio 7.0, allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a long request to TCP port 80. |
| Cross-site scripting (XSS) vulnerability in Advantech WebAccess (formerly BroadWin WebAccess) before 7.1 2013.05.30 allows remote authenticated users to inject arbitrary web script or HTML via unspecified vectors. |
| Absolute path traversal vulnerability in NTWebServer.exe in Indusoft Studio 7.0 and earlier and Advantech Studio 7.0 and earlier allows remote attackers to read arbitrary files via a full pathname in an argument to the sub_401A90 CreateFileW function. |
| SQL injection vulnerability in Advantech/BroadWin WebAccess 7.0 allows remote authenticated users to execute arbitrary SQL commands via a malformed URL. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-0234. |
| Multiple SQL injection vulnerabilities in Advantech/BroadWin WebAccess before 7.0 allow remote attackers to execute arbitrary SQL commands via crafted string input. |
| Advantech/BroadWin WebAccess before 7.0 allows remote attackers to trigger the extraction of arbitrary web content into a batch file on a client system, and execute this batch file, via unspecified vectors. |
| Buffer overflow in an ActiveX control in Advantech/BroadWin WebAccess before 7.0 might allow remote attackers to execute arbitrary code via a long string value in unspecified parameters. |
| Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the ping tool of the web-interface. |
| Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the device name field of the web-interface. |
| Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the device name input field, which can be triggered by authenticated users via a crafted POST request. |
| Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the NTP server input field, which can be triggered by authenticated users via a crafted POST request. |
| Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stack-based Buffer Overflow vulnerability, which can be triggered by authenticated users via a crafted POST request. |
|
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server.
|