Search Results (379 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-2072 1 Rockwellautomation 2 Powermonitor 1000, Powermonitor 1000 Firmware 2024-11-21 8.8 High
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product.  The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product.
CVE-2023-2071 1 Rockwellautomation 2 Factorytalk View, Panelview Plus 2024-11-21 9.8 Critical
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
CVE-2023-29464 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 8.2 High
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CVE-2023-29031 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 7 High
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29030 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 7 High
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29025 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 4.7 Medium
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
CVE-2023-29024 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 5.5 Medium
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product A cross site scripting vulnerability was discovered that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29023 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 7 High
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-27857 1 Rockwellautomation 1 Thinmanager 2024-11-21 7.5 High
In affected versions, a heap-based buffer over-read condition occurs when the message field indicates more data than is present in the message field in Rockwell Automation's ThinManager ThinServer.  An unauthenticated remote attacker can exploit this vulnerability to crash ThinServer.exe due to a read access violation.
CVE-2021-22665 1 Rockwellautomation 2 Drivetools Add-on Profiles, Drivetools Sp 2024-11-21 7.8 High
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.
CVE-2020-6980 1 Rockwellautomation 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more 2024-11-21 3.3 Low
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
CVE-2020-6967 1 Rockwellautomation 1 Factorytalk Services Platform 2024-11-21 9.8 Critical
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
CVE-2020-6111 1 Rockwellautomation 2 Micrologix 1100, Micrologix 1100 B Firmware 2024-11-21 7.5 High
An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN 10.000. A specially crafted packet can cause a major error, resulting in a denial of service. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-6088 1 Rockwellautomation 2 Flex Io 1794-aent\/b, Flex Io 1794-aent\/b Firmware 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Network Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-6087 1 Rockwellautomation 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability If the ANSI Extended Symbol Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required.
CVE-2020-6086 1 Rockwellautomation 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.If the Simple Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required.
CVE-2020-6085 1 Rockwellautomation 1 Flex I\/o 1794-aent 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability by sending an Electronic Key Segment with less than 0x18 bytes following the Key Format field.
CVE-2020-6084 1 Rockwellautomation 1 Flex I\/o 1794-aent 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability by sending an Electronic Key Segment with less bytes than required by the Key Format Table.
CVE-2020-6083 1 Rockwellautomation 2 Allen-bradley Flex Io 1794-aent\/b, Allen-bradley Flex Io 1794-aent\/b Firmware 2024-11-21 7.5 High
An exploitable denial of service vulnerability exists in the ENIP Request Path Port Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-5807 1 Rockwellautomation 1 Factorytalk Diagnostics 2024-11-21 7.5 High
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.