Search Results (30 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-1907 1 Pgadmin 1 Pgadmin 2025-08-27 8 High
A vulnerability was found in pgadmin. Users logging into pgAdmin running in server mode using LDAP authentication may be attached to another user's session if multiple connection attempts occur simultaneously.
CVE-2025-47928 2025-05-16 9.1 Critical
Spotipy is a Python library for the Spotify Web API. As of commit 4f5759dbfb4506c7b6280572a4db1aabc1ac778d, using `pull_request_target` on `.github/workflows/integration_tests.yml` followed by the checking out the head.sha of a forked PR can be exploited by attackers, since untrusted code can be executed having full access to secrets (from the base repo). By exploiting the vulnerability is possible to exfiltrate `GITHUB_TOKEN` and secrets `SPOTIPY_CLIENT_ID`, `SPOTIPY_CLIENT_SECRET`. In particular `GITHUB_TOKEN` which can be used to completely overtake the repo since the token has content write privileges. The `pull_request_target` in GitHub Actions is a major security concern—especially in public repositories—because it executes untrusted code from a PR, but with the context of the base repository, including access to its secrets. Commit 9dfb7177b8d7bb98a5a6014f8e6436812a47576f reverted the change that caused the issue.
CVE-2025-30073 2025-03-27 7.5 High
An issue was discovered in OPC cardsystems Webapp Aufwertung 2.1.0. The reference assigned to transactions can be reused. When completing a payment, the first or all transactions with the same reference are completed, depending on timing. This can be used to transfer more money onto employee cards than is paid.
CVE-2023-30861 2 Palletsprojects, Redhat 5 Flask, Openshift Ironic, Openstack and 2 more 2025-02-13 7.5 High
Flask is a lightweight WSGI web application framework. When all of the following conditions are met, a response containing data intended for one client may be cached and subsequently sent by the proxy to other clients. If the proxy also caches `Set-Cookie` headers, it may send one client's `session` cookie to other clients. The severity depends on the application's use of the session and the proxy's behavior regarding cookies. The risk depends on all these conditions being met. 1. The application must be hosted behind a caching proxy that does not strip cookies or ignore responses with cookies. 2. The application sets `session.permanent = True` 3. The application does not access or modify the session at any point during a request. 4. `SESSION_REFRESH_EACH_REQUEST` enabled (the default). 5. The application does not set a `Cache-Control` header to indicate that a page is private or should not be cached. This happens because vulnerable versions of Flask only set the `Vary: Cookie` header when the session is accessed or modified, not when it is refreshed (re-sent to update the expiration) without being accessed or modified. This issue has been fixed in versions 2.3.2 and 2.2.5.
CVE-2022-40210 1 Intel 1 Data Center Manager 2025-01-27 6.8 Medium
Exposure of data element to wrong session in the Intel DCM software before version 5.0.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-1223 4 Apple, Linux, Microsoft and 1 more 5 Macos, Linux Kernel, Windows and 2 more 2025-01-23 4.8 Medium
This vulnerability potentially allows unauthorized enumeration of information from the embedded device APIs. An attacker must already have existing knowledge of some combination of valid usernames, device names and an internal system key. For such an attack to be successful the system must be in a specific runtime state.
CVE-2024-27935 1 Deno 1 Deno 2025-01-03 7.2 High
Deno is a JavaScript, TypeScript, and WebAssembly runtime. Starting in version 1.35.1 and prior to version 1.36.3, a vulnerability in Deno's Node.js compatibility runtime allows for cross-session data contamination during simultaneous asynchronous reads from Node.js streams sourced from sockets or files. The issue arises from the re-use of a global buffer (BUF) in stream_wrap.ts used as a performance optimization to limit allocations during these asynchronous read operations. This can lead to data intended for one session being received by another session, potentially resulting in data corruption and unexpected behavior. This affects all users of Deno that use the node.js compatibility layer for network communication or other streams, including packages that may require node.js libraries indirectly. Version 1.36.3 contains a patch for this issue.
CVE-2024-38367 1 Cocoapods 1 Trunk.cocoapods.org 2024-11-21 8.2 High
trunk.cocoapods.org is the authentication server for the CoacoaPods dependency manager. Prior to commit d4fa66f49cedab449af9a56a21ab40697b9f7b97, the trunk sessions verification step could be manipulated for owner session hijacking Compromising a victim’s session will result in a full takeover of the CocoaPods trunk account. The threat actor could manipulate their pod specifications, disrupt the distribution of legitimate libraries, or cause widespread disruption within the CocoaPods ecosystem. This was patched server-side with commit d4fa66f49cedab449af9a56a21ab40697b9f7b97 in October 2023.
CVE-2024-7049 2 Open-webui, Openwebui 2 Open-webui, Open Webui 2024-10-17 5.4 Medium
In version v0.3.8 of open-webui/open-webui, a vulnerability exists where a token is returned when a user with a pending role logs in. This allows the user to perform actions without admin confirmation, bypassing the intended approval process.
CVE-2024-41977 1 Siemens 53 Ruggedcom Rcm1224 Firmware, Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware and 50 more 2024-08-23 7.1 High
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly enforce isolation between user sessions in their web server component. This could allow an authenticated remote attacker to escalate their privileges on the devices.