Search Results (57 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-39537 1 Juniper 7 Acx7020, Acx7024, Acx7024x and 4 more 2026-01-22 6.5 Medium
An Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Juniper Networks Junos OS Evolved on ACX 7000 Series allows an unauthenticated, network-based attacker to cause a limited information disclosure and availability impact to the device. Due to a wrong initialization, specific processes which should only be able to communicate internally within the device can be reached over the network via open ports. This issue affects Junos OS Evolved on ACX 7000 Series: * All versions before 21.4R3-S7-EVO, * 22.2-EVO versions before 22.2R3-S4-EVO, * 22.3-EVO versions before 22.3R3-S3-EVO, * 22.4-EVO versions before 22.4R3-S2-EVO, * 23.2-EVO versions before 23.2R2-EVO, * 23.4-EVO versions before 23.4R1-S1-EVO, 23.4R2-EVO.
CVE-2025-61939 1 Columbiaweather 2 Weather Microserver, Weather Microserver Firmware 2026-01-22 8.8 High
An unused function in MicroServer can start a reverse SSH connection to a vendor registered domain, without mutual authentication. An attacker on the local network with admin access to the web server, and the ability to manipulate DNS responses, can redirect the SSH connection to an attacker controlled device.
CVE-2025-33176 1 Nvidia 1 Runai 2025-11-06 6.2 Medium
NVIDIA RunAI for all platforms contains a vulnerability where a user could cause an improper restriction of communications channels on an adjacent network. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, and information disclosure.
CVE-2017-3891 1 Blackberry 1 Qnx Software Development Platform 2025-08-22 9.6 Critical
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.
CVE-2024-22315 1 Ibm 3 Storage Fusion, Storage Fusion Hci, Storage Fusion Hci For Watsonx 2025-08-19 4 Medium
IBM Fusion and IBM Fusion HCI 2.3.0 through 2.8.2 is vulnerable to insecure network connection by allowing an attacker who gains access to a Fusion container to establish an external network connection.
CVE-2022-43916 2 Ibm, Redhat 2 App Connect Enterprise Certified Container, Openshift 2025-08-13 6.8 Medium
IBM App Connect Enterprise Certified Container 7.1, 7.2, 8.0, 8.1, 8.2, 9.0, 9.1, 9.2, 10.0, 10.1, 11.0, 11.1, 11.2, 11.3, 11.4, 11.5, 11.6, 12.0, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, and 12.7 Pods do not restrict network egress for Pods that are used for internal infrastructure.
CVE-2025-22251 1 Fortinet 1 Fortios 2025-07-25 3 Low
An improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in FortiOS 7.6.0, 7.4.0 through 7.4.5, 7.2 all versions, 7.0 all versions, 6.4 all versions may allow an unauthenticated attacker to inject unauthorized sessions via crafted FGSP session synchronization packets.
CVE-2025-29986 1 Dell 1 Common Event Enabler 2025-07-15 8.3 High
Dell Common Event Enabler, version(s) CEE 9.0.0.0, contain(s) an Improper Restriction of Communication Channel to Intended Endpoints vulnerability in the Common Anti-Virus Agent (CAVA). An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
CVE-2024-43571 1 Microsoft 1 Windows 11 24h2 2025-07-08 5.6 Medium
Sudo for Windows Spoofing Vulnerability
CVE-2021-38487 1 Rti 3 Connext Dds Micro, Connext Professional, Connext Secure 2025-06-23 8.2 High
RTI Connext Professional versions 4.1 to 6.1.0, and Connext Micro versions 2.4 and later are vulnerable when an attacker sends a specially crafted packet to flood target devices with unwanted traffic. This may result in a denial-of-service condition and information exposure.
CVE-2025-32886 1 Gotenna 3 Gotenna, Mesh, Mesh Firmware 2025-06-20 4 Medium
An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. All packets sent over RF are also sent over UART with USB Shell, allowing someone with local access to gain information about the protocol and intercept sensitive data.
CVE-2025-35978 2025-06-12 N/A
Improper restriction of communication channel to intended endpoints issue exists in UpdateNavi V1.4 L10 to L33 and UpdateNaviInstallService Service 1.2.0091 to 1.2.0125. If a local authenticated attacker send malicious data, an arbitrary registry value may be modified or arbitrary code may be executed.
CVE-2025-48999 1 Dataease 1 Dataease 2025-06-05 8.8 High
DataEase is an open source business intelligence and data visualization tool. A bypass of CVE-2025-46566's patch exists in versions prior to 2.10.10. In a malicious payload, `getUrlType()` retrieves `hostName`. Since the judgment statement returns false, it will not enter the if statement and will not be filtered. The payload can be directly concatenated at the replace location to construct a malicious JDBC statement. Version 2.10.10 contains a patch for the issue.
CVE-2025-46566 1 Dataease 1 Dataease 2025-05-28 9.8 Critical
DataEase is an open-source BI tool alternative to Tableau. Prior to version 2.10.9, authenticated users can complete RCE through the backend JDBC link. This issue has been patched in version 2.10.9.
CVE-2018-10596 1 Medtronic 2 2090 Carelink Programmer, 2090 Carelink Programmer Firmware 2025-05-22 7.1 High
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.
CVE-2025-23178 2025-05-02 7.6 High
CWE-923: Improper Restriction of Communication Channel to Intended Endpoints
CVE-2025-31144 2025-04-29 N/A
Quick Agent V3 and Quick Agent V2 contain an issue with improper restriction of communication channel to intended endpoints. If exploited, a remote unauthenticated attacker may attempt to log in to an arbitrary host via Windows system where the product is running.
CVE-2022-2835 1 Coredns.io 1 Coredns 2025-03-07 4.4 Medium
A flaw was found in coreDNS. This flaw allows a malicious user to reroute internal calls to some internal services that were accessed by the FQDN in a format of <service>.<namespace>.svc.
CVE-2022-2837 1 Coredns.io 1 Coredns 2025-03-07 6.1 Medium
A flaw was found in coreDNS. This flaw allows a malicious user to redirect traffic intended for external top-level domains (TLD) to a pod they control by creating projects and namespaces that match the TLD.
CVE-2024-26131 1 Element 1 Element 2025-02-14 8.4 High
Element Android is an Android Matrix Client. Element Android version 1.4.3 through 1.6.10 is vulnerable to intent redirection, allowing a third-party malicious application to start any internal activity by passing some extra parameters. Possible impact includes making Element Android display an arbitrary web page, executing arbitrary JavaScript; bypassing PIN code protection; and account takeover by spawning a login screen to send credentials to an arbitrary home server. This issue is fixed in Element Android 1.6.12. There is no known workaround to mitigate the issue.