| Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session. |
| D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0644 /var/etc/shadow (aka the /etc/shadow symlink target) permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices use the same hardcoded /etc/stunnel.key private key across different customers' installations, which allows remote attackers to defeat the HTTPS cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file. |
| The SMI-S service in Dell Storage Manager versions earlier than 16.3.20 (aka 2016 R3.20) is protected using a hard-coded password. A remote user with the knowledge of the password might potentially disable the SMI-S service via HTTP requests, affecting storage management and monitoring functionality via the SMI-S interface. This issue, aka DSM-30415, only affects a Windows installation of the Data Collector (not applicable to the virtual appliance). |
| An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source. |
| CloudForms Management Engine before 5.8 includes a default SSL/TLS certificate. |
| ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session. |
| Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it. |
| Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607. |
| An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234. |
| D-Link DGS-1100 devices with Rev.B firmware 1.01.018 have a hardcoded SSL private key, which allows man-in-the-middle attackers to spoof devices by hijacking an HTTPS session. |
| A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks. |