Search Results (79 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-46997 1 Passhunt Project 1 Passhunt 2025-04-21 9.8 Critical
Passhunt commit 54eb987d30ead2b8ebbf1f0b880aa14249323867 was discovered to contain a code execution backdoor via the request package. This vulnerability allows attackers to access sensitive user information and digital currency keys, as well as escalate privileges.
CVE-2022-46996 1 Vsphere Selfuse Project 1 Vsphere Selfuse 2025-04-21 9.8 Critical
vSphere_selfuse commit 2a9fe074a64f6a0dd8ac02f21e2f10d66cac5749 was discovered to contain a code execution backdoor via the request package. This vulnerability allows attackers to access sensitive user information and digital currency keys, as well as escalate privileges.
CVE-2022-1741 1 Dominionvoting 2 Democracy Suite, Imagecast X 2025-04-17 6.8 Medium
The tested version of Dominion Voting Systems ImageCast X has a Terminal Emulator application which could be leveraged by an attacker to gain elevated privileges on a device and/or install malicious code.
CVE-2021-4229 1 Ua-parser-js Project 1 Ua-parser-js 2025-04-15 5 Medium
A vulnerability was found in ua-parser-js 0.7.29/0.8.0/1.0.0. It has been rated as critical. This issue affects the crypto mining component which introduces a backdoor. Upgrading to version 0.7.30, 0.8.1 and 1.0.1 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2017-20082 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2025-04-15 5.5 Medium
A vulnerability, which was classified as problematic, has been found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832. This issue affects some unknown processing. The manipulation leads to backdoor. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2017-20083 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2025-04-15 5.3 Medium
A vulnerability, which was classified as critical, was found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832. Affected is an unknown function of the component SSH Server. The manipulation leads to backdoor. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2017-20084 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2025-04-15 5.3 Medium
A vulnerability has been found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832 and classified as critical. Affected by this vulnerability is an unknown functionality of the component KNX Group Address. The manipulation leads to backdoor. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2025-32370 1 Kentico 1 Xperience 2025-04-08 7.2 High
Kentico Xperience before 13.0.178 has a specific set of allowed ContentUploader file extensions for unauthenticated uploads; however, because .zip is processed through TryZipProviderSafe, there is additional functionality to create files with other extensions. NOTE: this is a separate issue not necessarily related to SVG or XSS.
CVE-2023-22316 1 Pixela 2 Pix-rt100, Pix-rt100 Firmware 2025-04-04 6.5 Medium
Hidden functionality vulnerability in PIX-RT100 versions RT100_TEQ_2.1.1_EQ101 and RT100_TEQ_2.1.2_EQ101 allows a network-adjacent attacker to access the product via undocumented Telnet or SSH services.
CVE-2022-47767 1 Solar-log 18 Solar-log 1000, Solar-log 1000 Firmware, Solar-log 1000 Pm\+ and 15 more 2025-04-01 9.8 Critical
A backdoor in Solar-Log Gateway products allows remote access via web panel gaining super administration privileges to the attacker. This affects Solar-Log devices that use firmware version v4.2.7 up to v5.1.1 (included). This does not exist in SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base.
CVE-2022-3843 1 Wago 2 852-111\/000-001, 852-111\/000-001 Firmware 2025-03-18 9.1 Critical
In WAGO Unmanaged Switch (852-111/000-001) in firmware version 01 an undocumented configuration interface without authorization allows an remote attacker to read system information and configure a limited set of parameters.
CVE-2021-36403 1 Moodle 1 Moodle 2025-03-07 5.3 Medium
In Moodle, in some circumstances, email notifications of messages could have the link back to the original message hidden by HTML, which may pose a phishing risk.
CVE-2022-38452 1 Netgear 2 Rbs750, Rbs750 Firmware 2025-02-26 7.2 High
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
CVE-2025-1204 2025-02-25 N/A
The "update" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.
CVE-2025-0675 2025-02-12 7.5 High
Multiple Elber products suffer from an unauthenticated device configuration and client-side hidden functionality disclosure.
CVE-2023-25183 1 Snapone 2 Orvc, Ovrc-300-pro 2025-01-16 8.3 High
In Snap One OvrC Pro versions prior to 7.2, when logged into the superuser account, a new functionality appears that could allow users to execute arbitrary commands on the hub device.
CVE-2024-5514 1 Minmax 1 Minmax 2024-11-25 9.8 Critical
MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs.
CVE-2024-6045 1 Dlink 15 E15 Firmware, E30 Firmware, G403 Firmware and 12 more 2024-11-21 8.8 High
Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware.
CVE-2024-5633 2024-11-21 N/A
Longse model LBH30FE200W cameras, as well as products based on this device, provide an unrestricted access for an attacker located in the same local network to an undocumented binary service CoolView on one of the ports.  An attacker with a knowledge of the available commands is able to perform read/write operations on the device's memory, which might result in e.g. bypassing telnet login and obtaining full access to the device.
CVE-2024-3016 2024-11-21 9.1 Critical
NEC Platforms DT900 and DT900S Series 5.0.0.0 – v5.3.4.4, v5.4.0.0 – v5.6.0.20 allows an attacker to access a non-documented the system settings to change settings via local network with unauthenticated user.