Search Results (2198 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-7115 1 Rowboatlabs 1 Rowboat 2025-07-13 7.3 High
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
CVE-2024-36457 1 Broadcom 1 Symantec Privileged Access Management 2025-07-13 N/A
The vulnerability allows an attacker to bypass the authentication requirements for a specific PAM endpoint.
CVE-2023-25493 1 Lenovo 1 Bios 2025-07-13 6.7 Medium
A potential vulnerability was reported in the BIOS update tool driver for some Desktop, Smart Edge, Smart Office, and ThinkStation products that could allow a local user with elevated privileges to execute arbitrary code.
CVE-2024-12957 1 Asus 1 Armoury Crate 2025-07-12 N/A
A file handling command vulnerability in certain versions of Armoury Crate may result in arbitrary file deletion. Refer to the '01/23/2025 Security Update for Armoury Crate App' section on the ASUS Security Advisory for more information.
CVE-2024-39364 1 Advantech 1 Adam-5630 2025-07-12 6.3 Medium
Advantech ADAM-5630 has built-in commands that can be executed without authenticating the user. These commands allow for restarting the operating system, rebooting the hardware, and stopping the execution. The commands can be sent to a simple HTTP request and are executed by the device automatically, without discrimination of origin or level of privileges of the user sending the commands.
CVE-2024-23815 1 Siemens 1 Desigo Cc 2025-07-12 7.5 High
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)
CVE-2024-3219 1 Python Software Foundation 1 Cpython 2025-07-12 N/A
The “socket” module provides a pure-Python fallback to the socket.socketpair() function for platforms that don’t support AF_UNIX, such as Windows. This pure-Python implementation uses AF_INET or AF_INET6 to create a local connected pair of sockets. The connection between the two sockets was not verified before passing the two sockets back to the user, which leaves the server socket vulnerable to a connection race from a malicious local peer. Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included.
CVE-2025-32440 1 Netalertx 1 Netalertx 2025-07-11 10 Critical
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
CVE-2025-25268 1 Phoenixcontact 8 Charx Sec-3000, Charx Sec-3000 Firmware, Charx Sec-3050 and 5 more 2025-07-11 8.8 High
An unauthenticated adjacent attacker can modify configuration by sending specific requests to an API-endpoint resulting in read and write access due to missing authentication.
CVE-2025-44039 1 Cpplusworld 2 Cp-xr-de21-s, Cp-xr-de21-s Firmware 2025-07-11 5.1 Medium
CP-XR-DE21-S -4G Router Firmware version 1.031.022 was discovered to contain insecure protections for its UART console. This vulnerability allows local attackers to connect to the UART port via a serial connection, read all boot sequence, and revealing internal system details and sensitive information without any authentication.
CVE-2024-38143 1 Microsoft 13 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 10 more 2025-07-10 4.2 Medium
Windows WLAN AutoConfig Service Elevation of Privilege Vulnerability
CVE-2024-5718 1 Logsign 2 Unified Secops, Unified Secops Platform 2025-07-10 8.1 High
Logsign Unified SecOps Platform Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Logsign Unified SecOps Platform. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the cluster HTTP API, which listens on TCP port 1924 by default when enabled. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-24166.
CVE-2024-5721 1 Logsign 2 Unified Secops, Unified Secops Platform 2025-07-10 8.1 High
Logsign Unified SecOps Platform Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Logsign Unified SecOps Platform. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the cluster HTTP API, which listens on TCP port 1924 when enabled. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-24169.
CVE-2025-3498 2025-07-10 9.9 Critical
An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).
CVE-2023-51587 1 Voltronicpower 1 Viewpower 2025-07-09 N/A
Voltronic Power ViewPower getModbusPassword Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the getModbusPassword method. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-22073.
CVE-2025-48469 1 Advantech 6 Wise-4010lan, Wise-4010lan Firmware, Wise-4050lan and 3 more 2025-07-09 9.6 Critical
Successful exploitation of the vulnerability could allow an unauthenticated attacker to upload firmware through a public update page, potentially leading to backdoor installation or privilege escalation.
CVE-2025-34089 2025-07-08 N/A
An unauthenticated remote code execution vulnerability exists in Remote for Mac, a macOS remote control utility developed by Aexol Studio, in versions up to and including 2025.7. When the application is configured with authentication disabled (i.e., the "Allow unknown devices" option is enabled), the /api/executeScript endpoint is exposed without access control. This allows unauthenticated remote attackers to inject arbitrary AppleScript payloads via the X-Script HTTP header, resulting in code execution using do shell script. Successful exploitation grants attackers the ability to run arbitrary commands on the macOS host with the privileges of the Remote for Mac background process.
CVE-2024-49052 1 Microsoft 1 Azure Functions 2025-07-08 8.2 High
Missing authentication for critical function in Microsoft Azure PolicyWatch allows an unauthorized attacker to elevate privileges over a network.
CVE-2024-43488 1 Microsoft 1 Visual Studio Code 2025-07-08 8.8 High
Missing authentication for critical function in Visual Studio Code extension for Arduino allows an unauthenticated attacker to perform remote code execution through network attack vector.
CVE-2025-32876 1 Yftech 2 Coros Pace 3, Coros Pace 3 Firmware 2025-07-08 6.8 Medium
An issue was discovered on COROS PACE 3 devices through 3.0808.0. The BLE implementation of the COROS smartwatch does not support LE Secure Connections and instead enforces BLE Legacy Pairing. In BLE Legacy Pairing, the Short-Term Key (STK) can be easily guessed. This requires knowledge of the Temporary Key (TK), which, in the case of the COROS Pace 3, is set to 0 due to the Just Works pairing method. An attacker within Bluetooth range can therefore perform sniffing attacks, allowing eavesdropping on the communication.