Search Results (20311 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-31891 2 Debian, Siemens 6 Debian Linux, Desigo Cc, Gma-manager and 3 more 2024-11-21 10.0 Critical
A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges.
CVE-2021-31888 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
CVE-2021-31887 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
CVE-2021-31886 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
CVE-2021-31875 1 Cesanta 1 Mongooseos Mjs 2024-11-21 9.8 Critical
In mjs_json.c in Cesanta MongooseOS mJS 1.26, a maliciously formed JSON string can trigger an off-by-one heap-based buffer overflow in mjs_json_parse, which can potentially lead to redirection of control flow. NOTE: the original reporter disputes the significance of this finding because "there isn’t very much of an opportunity to exploit this reliably for an information leak, so there isn’t any real security impact."
CVE-2021-31837 1 Mcafee 1 Getsusp 2024-11-21 8.8 High
Memory corruption vulnerability in the driver file component in McAfee GetSusp prior to 4.0.0 could allow a program being investigated on the local machine to trigger a buffer overflow in GetSusp, leading to the execution of arbitrary code, potentially triggering a BSOD.
CVE-2021-31811 4 Apache, Fedoraproject, Oracle and 1 more 13 Pdfbox, Fedora, Banking Corporate Lending Process Management and 10 more 2024-11-21 5.5 Medium
In Apache PDFBox, a carefully crafted PDF file can trigger an OutOfMemory-Exception while loading the file. This issue affects Apache PDFBox version 2.0.23 and prior 2.0.x versions.
CVE-2021-31802 1 Netgear 2 R7000, R7000 Firmware 2024-11-21 8.8 High
NETGEAR R7000 1.0.11.116 devices have a heap-based Buffer Overflow that is exploitable from the local network without authentication. The vulnerability exists within the handling of an HTTP request. An attacker can leverage this to execute code as root. The problem is that a user-provided length value is trusted during a backup.cgi file upload. The attacker must add a \n before the Content-Length header.
CVE-2021-31799 4 Debian, Oracle, Redhat and 1 more 8 Debian Linux, Jd Edwards Enterpriseone Tools, Enterprise Linux and 5 more 2024-11-21 7 High
In RDoc 3.11 through 6.x before 6.3.1, as distributed with Ruby through 3.0.1, it is possible to execute arbitrary code via | and tags in a filename.
CVE-2021-31795 1 Pvrsrvkm.ko Project 1 Pvrsrvkm.ko 2024-11-21 7.0 High
The PowerVR GPU kernel driver in pvrsrvkm.ko through 2021-04-24 for the Linux kernel, as used on Alcatel 1S phones, allows attackers to overwrite heap memory via PhysmemNewRamBackedPMR.
CVE-2021-31784 2 Opendesign, Siemens 2 Drawings Sdk, Comos 2024-11-21 7.8 High
An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6 on all supported by ODA platforms in static configuration. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution.
CVE-2021-31769 1 Myq-solution 1 Myq Server 2024-11-21 8.8 High
MyQ Server in MyQ X Smart before 8.2 allows remote code execution by unprivileged users because administrative session data can be read in the %PROGRAMFILES%\MyQ\PHP\Sessions directory. The "Select server file" feature is only intended for administrators but actually does not require authorization. An attacker can inject arbitrary OS commands (such as commands to create new .php files) via the Task Scheduler component.
CVE-2021-31758 1 Tenda 2 Ac11, Ac11 Firmware 2024-11-21 9.8 Critical
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request.
CVE-2021-31757 1 Tenda 2 Ac11, Ac11 Firmware 2024-11-21 9.8 Critical
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request.
CVE-2021-31756 1 Tenda 2 Ac11, Ac11 Firmware 2024-11-21 9.8 Critical
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable.
CVE-2021-31698 1 Quectel 2 Eg25-g, Eg25-g Firmware 2024-11-21 9.8 Critical
Quectel EG25-G devices through 202006130814 allow executing arbitrary code remotely by using an AT command to place shell metacharacters in quectel_handle_fumo_cfg input in atfwd_daemon.
CVE-2021-31684 3 Json-smart Project, Oracle, Redhat 4 Json-smart-v1, Json-smart-v2, Utilities Framework and 1 more 2024-11-21 7.5 High
A vulnerability was discovered in the indexOf function of JSONParserByteArray in JSON Smart versions 1.3 and 2.4 which causes a denial of service (DOS) via a crafted web request.
CVE-2021-31616 1 Shapeshift 2 Keepkey, Keepkey Firmware 2024-11-21 8.8 High
Insufficient length checks in the ShapeShift KeepKey hardware wallet firmware before 7.1.0 allow a stack buffer overflow via crafted messages. The overflow in ethereum_extractThorchainSwapData() in ethereum.c can circumvent stack protections and lead to code execution. The vulnerable interface is reachable remotely over WebUSB.
CVE-2021-31607 2 Fedoraproject, Saltstack 2 Fedora, Salt 2024-11-21 7.8 High
In SaltStack Salt 2016.9 through 3002.6, a command injection vulnerability exists in the snapper module that allows for local privilege escalation on a minion. The attack requires that a file is created with a pathname that is backed up by snapper, and that the master calls the snapper.diff function (which executes popen unsafely).
CVE-2021-31605 1 Openvpn-monitor Project 1 Openvpn-monitor 2024-11-21 7.5 High
furlongm openvpn-monitor through 1.1.3 allows %0a command injection via the OpenVPN management interface socket. This can shut down the server via signal%20SIGTERM.