CVE-2017-7903 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2025-04-20 N/A
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
CVE-2017-1224 1 Ibm 1 Bigfix Platform 2025-04-20 N/A
IBM Tivoli Endpoint Manager uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 123903.
CVE-2015-0575 1 Google 1 Android 2025-04-20 N/A
In all Qualcomm products with Android releases from CAF using the Linux kernel, insecure ciphersuites were included in the default configuration.
CVE-2016-2879 1 Ibm 1 Qradar Security Information And Event Manager 2025-04-20 N/A
IBM QRadar 7.2 uses outdated hashing algorithms to hash certain passwords, which could allow a local user to obtain and decrypt user credentials. IBM Reference #: 1997341.
CVE-2016-3019 1 Ibm 1 Security Access Manager 9.0 Firmware 2025-04-20 N/A
IBM Security Access Manager for Web 9.0.0 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 114462.
CVE-2016-3034 1 Ibm 1 Security Appscan Source 2025-04-20 N/A
IBM AppScan Source uses a one-way hash without salt to encrypt highly sensitive information, which could allow a local attacker to decrypt information more easily.
CVE-2016-4685 1 Apple 1 Iphone Os 2025-04-20 N/A
An issue was discovered in certain Apple products. iOS before 10.1 is affected. The issue involves the "iTunes Backup" component, which improperly hashes passwords, making it easier to decrypt files.
CVE-2016-4693 1 Apple 3 Iphone Os, Mac Os X, Watchos 2025-04-20 N/A
An issue was discovered in certain Apple products. iOS before 10.2 is affected. macOS before 10.12.2 is affected. watchOS before 3.1.3 is affected. The issue involves the "Security" component, which makes it easier for attackers to bypass cryptographic protection mechanisms by leveraging use of the 3DES cipher.
CVE-2017-1179 1 Ibm 1 Bigfix Security Compliance Analytics 2025-04-20 N/A
IBM BigFix Compliance Analytics 1.9.79 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 123431.
CVE-2017-1271 1 Ibm 1 Security Guardium 2025-04-20 N/A
IBM Security Guardium 9.0, 9.1, and 9.5 supports interaction between multiple actors and allows those actors to negotiate which algorithm should be used as a protection mechanism such as encryption or authentication, but it does not select the strongest algorithm that is available to both parties. IBM X-Force ID: 124746.
CVE-2017-17436 1 Vaulteksafe 2 Vt20i, Vt20i Firmware 2025-04-20 N/A
An issue was discovered in the software on Vaultek Gun Safe VT20i products. There is no encryption of the session between the Android application and the safe. The website and marketing materials advertise that this communication channel is encrypted with "Highest Level Bluetooth Encryption" and "Data transmissions are secure via AES256 bit encryption." These claims, however, are not true. Moreover, AES256 bit encryption is not supported in the Bluetooth Low Energy (BLE) standard, so it would have to be at the application level. This lack of encryption allows an individual to learn the passcode by eavesdropping on the communications between the application and the safe.
CVE-2020-14481 1 Rockwellautomation 1 Factorytalk View 2025-04-17 7.8 High
The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.
CVE-2022-38659 2 Hcltech, Microsoft 2 Bigfix Platform, Windows 2025-04-17 6 Medium
In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
CVE-2022-21800 1 Airspan 9 A5x, A5x Firmware, C5c and 6 more 2025-04-16 6.5 Medium
MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords.
CVE-2020-10636 1 Emerson 1 Openenterprise Scada Server 2025-04-16 6.5 Medium
Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained.
CVE-2021-32945 1 Auvesy-mdt 2 Autosave, Autosave For System Platform 2025-04-16 7.5 High
An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06.
CVE-2022-1318 1 Carrier 2 Hills Comnav, Hills Comnav Firmware 2025-04-16 6.2 Medium
Hills ComNav version 3002-19 suffers from a weak communication channel. Traffic across the local network for the configuration pages can be viewed by a malicious actor. The size of certain communications packets are predictable. This would allow an attacker to learn the state of the system if they can observe the traffic. This would be possible even if the traffic were encrypted, e.g., using WPA2, as the packet sizes would remain observable. The communication encryption scheme is theoretically sound, but is not strong enough for the level of protection required.
CVE-2020-16235 1 Emerson 1 Openenterprise Scada Server 2025-04-16 3.8 Low
Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained.
CVE-2022-2758 1 Ls-electric 469 Gm7, Gm7 Firmware, Gm7u and 466 more 2025-04-16 6.5 Medium
Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic.