Export limit exceeded: 16381 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 43676 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (43676 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-55152 | 1 Oakserver | 1 Oak | 2026-04-15 | 5.3 Medium |
| oak is a middleware framework for Deno's native HTTP server, Deno Deploy, Node.js 16.5 and later, Cloudflare Workers and Bun. In versions 17.1.5 and below, it's possible to significantly slow down an oak server with specially crafted values of the x-forwarded-proto or x-forwarded-for headers. | ||||
| CVE-2025-55159 | 1 Tokio | 1 Slab | 2026-04-15 | 4.0 Medium |
| slab is a pre-allocated storage for a uniform data type. In version 0.4.10, the get_disjoint_mut method incorrectly checked if indices were within the slab's capacity instead of its length, allowing access to uninitialized memory. This could lead to undefined behavior or potential crashes. This has been fixed in slab 0.4.11. A workaround for this issue involves to avoid using get_disjoint_mut with indices that might be beyond the slab's actual length. | ||||
| CVE-2025-55164 | 1 Content-security-policy-parser Project | 1 Content-security-policy-parser | 2026-04-15 | N/A |
| content-security-policy-parser parses content security policy directives. A prototype pollution vulnerability exists in versions 0.5.0 and earlier, wherein if a policy name is called __proto__, one can override the Object prototype. This issue has been patched in version 0.6.0. A workaround involves disabling prototype method in NodeJS, neutralizing all possible prototype pollution attacks. Provide either --disable-proto=delete (recommended) or --disable-proto=throw as an argument to node to enable this feature. | ||||
| CVE-2025-55195 | 1 Denoland | 1 Std | 2026-04-15 | 7.3 High |
| @std/toml is the Deno Standard Library. Prior to version 1.0.9, an attacker can pollute the prototype chain in Node.js runtime and Browser when parsing untrusted TOML data, thus achieving Prototype Pollution (PP) vulnerability. This is because the library is merging an untrusted object with an empty object, which by default the empty object has the prototype chain. This issue has been patched in version 1.0.9. | ||||
| CVE-2025-52622 | 1 Hcltech | 1 Bigfix Saas | 2026-04-15 | 5.4 Medium |
| The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks. | ||||
| CVE-2012-10043 | 1 Actfax | 1 Actfax | 2026-04-15 | N/A |
| A stack-based buffer overflow vulnerability exists in ActFax Server version 4.32, specifically in the "Import Users from File" functionality of the client interface. The application fails to properly validate the length of tab-delimited fields in .exp files, leading to unsafe usage of strcpy() during CSV parsing. An attacker can exploit this vulnerability by crafting a malicious .exp file and importing it using the default character set "ECMA-94 / Latin 1 (ISO 8859)". Successful exploitation may result in arbitrary code execution, leading to full system compromise. User interaction is required to trigger the vulnerability. | ||||
| CVE-2025-52557 | 2026-04-15 | N/A | ||
| Mail-0's Zero is an open-source email solution. In version 0.8 it's possible for an attacker to craft an email that executes javascript leading to session hijacking due to improper sanitization. This issue has been patched in version 0.81. | ||||
| CVE-2025-7704 | 1 Supermicro | 1 Bmc | 2026-04-15 | 5.4 Medium |
| Supermicro BMC Insyde SMASH shell program has a stacked-based overflow vulnerability | ||||
| CVE-2025-7677 | 1 Abb | 3 Aspect Enterprise, Matrix Series, Nexus Series | 2026-04-15 | 5.9 Medium |
| A denial-of-service (DoS) attack is possible if access to the local network is provided to unauthorized users. This is due to a buffer copy issue that may lead to a software crash. This issue affects all versions of ASPECT. | ||||
| CVE-2025-41245 | 1 Vmware | 3 Aria Operations, Cloud Foundation, Tools | 2026-04-15 | 4.9 Medium |
| VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations. | ||||
| CVE-2025-10207 | 1 Abb | 1 Flxeon | 2026-04-15 | 7.2 High |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. | ||||
| CVE-2025-69674 | 1 Cdatatec | 1 Fd614gs3-r850 | 2026-04-15 | 8.8 High |
| Buffer Overflow vulnerability in CDATA FD614GS3-R850 V3.2.7_P161006 (Build.0333.250211) allows an attacker to execute arbitrary code via the node_mac, node_opt, opt_param, and domainblk parameters of the mesh_node_config and domiainblk_config modules | ||||
| CVE-2025-13084 | 1 Opto 22 | 3 Groov View Server, Grv-epic-pr1 Firmware, Grv-epic-pr2 Firmware | 2026-04-15 | 7.6 High |
| The users endpoint in the groov View API returns a list of all users and associated metadata including their API keys. This endpoint requires an Editor role to access and will display API keys for all users, including Administrators. | ||||
| CVE-2025-6761 | 1 Kingdee | 1 Cloud-starry-sky | 2026-04-15 | 7.3 High |
| A vulnerability was found in Kingdee Cloud-Starry-Sky Enterprise Edition 6.x/7.x/8.x/9.0. It has been rated as critical. Affected by this issue is the function plugin.buildMobilePopHtml of the file \k3\o2o\bos\webapp\action\DynamicForm 4 Action.class of the component Freemarker Engine. The manipulation leads to improper neutralization of special elements used in a template engine. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The vendor explains, that in the fixed release "Freemarker is set to 'ALLOWS_NOTHING_RESOLVER' to not parse any classes." | ||||
| CVE-2025-12818 | 1 Postgresql | 1 Postgresql | 2026-04-15 | 5.9 Medium |
| Integer wraparound in multiple PostgreSQL libpq client library functions allows an application input provider or network peer to cause libpq to undersize an allocation and write out-of-bounds by hundreds of megabytes. This results in a segmentation fault for the application using libpq. Versions before PostgreSQL 18.1, 17.7, 16.11, 15.15, 14.20, and 13.23 are affected. | ||||
| CVE-2025-3947 | 2026-04-15 | 8.2 High | ||
| The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. | ||||
| CVE-2025-68130 | 1 Trpc | 1 Trpc | 2026-04-15 | N/A |
| tRPC allows users to build and consume fully typesafe APIs without schemas or code generation. Starting in version 10.27.0 and prior to versions 10.45.3 and 11.8.0, a A prototype pollution vulnerability exists in `@trpc/server`'s `formDataToObject` function, which is used by the Next.js App Router adapter. An attacker can pollute `Object.prototype` by submitting specially crafted FormData field names, potentially leading to authorization bypass, denial of service, or other security impacts. Note that this vulnerability is only present when using `experimental_caller` / `experimental_nextAppDirCaller`. Versions 10.45.3 and 11.8.0 fix the issue. | ||||
| CVE-2025-68816 | 1 Linux | 1 Linux Kernel | 2026-04-15 | 5.6 Medium |
| In the Linux kernel, the following vulnerability has been resolved: net/mlx5: fw_tracer, Validate format string parameters Add validation for format string parameters in the firmware tracer to prevent potential security vulnerabilities and crashes from malformed format strings received from firmware. The firmware tracer receives format strings from the device firmware and uses them to format trace messages. Without proper validation, bad firmware could provide format strings with invalid format specifiers (e.g., %s, %p, %n) that could lead to crashes, or other undefined behavior. Add mlx5_tracer_validate_params() to validate that all format specifiers in trace strings are limited to safe integer/hex formats (%x, %d, %i, %u, %llx, %lx, etc.). Reject strings containing other format types that could be used to access arbitrary memory or cause crashes. Invalid format strings are added to the trace output for visibility with "BAD_FORMAT: " prefix. | ||||
| CVE-2025-6751 | 1 Linksys | 1 E8450 | 2026-04-15 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Linksys E8450 up to 1.2.00.360516. This affects the function set_device_language of the file portal.cgi of the component HTTP POST Request Handler. The manipulation of the argument dut_language leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-5941 | 1 Netskope | 1 Netskope | 2026-04-15 | N/A |
| Netskope is notified about a potential gap in its agent (NS Client) in which a malicious actor could trigger a memory leak by sending a crafted DNS packet to a machine. A successful exploitation may require administrative privileges on the machine, based on the exact configuration. A successful exploit can potentially result in user-controllable memory being leaked in a domain name stored on the local machine. | ||||